CASE REPORT

Elevated Intraocular Pressure after Descemet Stripping Automated Endothelial Keratoplasty in Patients with a Trabeculectomy: A Case Series

Mariana Patricia Hardin Sheales, Elsie Chan, Ghee Soon Ang, Yu Xiang George Kong

Keywords : Cornea, Descemet stripping automated endothelial keratoplasty, Glaucoma, Intraocular pressure, Trabeculectomy

Citation Information : Hardin Sheales MP, Chan E, Ang GS, George Kong YX. Elevated Intraocular Pressure after Descemet Stripping Automated Endothelial Keratoplasty in Patients with a Trabeculectomy: A Case Series. J Curr Glaucoma Pract 2015; 9 (3):100-103.

DOI: 10.5005/jp-journals-10008-1193

License: CC BY-NC 4.0

Published Online: 01-08-2019

Copyright Statement:  Copyright © 2015; The Author(s).


Abstract

We report a case series of three patients with previous trabeculectomies who developed elevated intraocular pressure (IOP) in the immediate postoperative period after routine Descemet stripping automated endothelial keratoplasty (DSAEK). All patients had functioning trabeculectomies preoperatively, and developed elevated IOP between 41 and 69 mm Hg within 24 hours following DSAEK surgery. The IOP was successfully controlled in all patients with topical IOP-lowering medications and oral acetazolamide, with the addition of ocular massage and release of aqueous for two patients. Thereafter, all patients maintained well-controlled IOPs. Patients with trabeculectomies should be followed-up closely immediately after DSAEK to monitor for raised IOP. The mechanism for this pressure rise is uncertain, but may involve air in the trabeculectomy sclerostomy or bleb resulting in blockage of aqueous flow.


PDF Share
  1. Belkin A, Nesher R, Segev F. Postoperative trendelenburg position for graft adherence after Descemets stripping automated endothelial keratoplasty. Cornea 2013 Nov; 32(11):1509-1511.
  2. Goshe J, Terry M, Li J, Straiko M, Davis-Boozer D. Graft dislocation and hypotony after Descemet's stripping automated endothelial keratoplasty in patients with previous glaucoma surgery. Ophthalmology 2012 Jun;119(6):1130-1133.
  3. Ide T, Yoo S, Leng T, O'Brien T. Subconjunctival air leakage after Descemet's stripping automated endothelial keratoplasty in a post-trabeculectomy eye. Open J Ophthalmol 2009 Jan; 9(3):1-2.
  4. Hau S, Barton K. Corneal complications of glaucoma surgery. Curr Opin Ophthalmol 2009 Mar;20(2):131-136.
  5. Aldave A, Chen J, Zaman A, Deng S, Yu F. Outcomes after DSEK in 101 eyes with previous trabeculectomy and tube shunt implantation. Cornea 2014 Mar;33(3):223-229.
  6. Esquenazi S, Rand W. Safety of DSAEK in patients with previous glaucoma filtering surgery. J Glaucoma 2010 Mar; 19(3):219-220.