ORIGINAL RESEARCH |
https://doi.org/10.5005/jp-journals-10078-1441 |
Superonasal vs Inferonasal Subconjunctival Gel Stent Placement in Patients with Glaucoma
1Department of Ophthalmology and Visual Sciences, University of Nebraska Medical Center, Nebraska, United States
2Department of Ophthalmology, Hiawatha Eye Clinic, Hiawatha, Iowa, United States
3-5Department of Ophthalmology, Vance Thompson Vision, Sioux Falls, South Dakota, United States
Corresponding Author: Brandon L Vander Zee, Department of Ophthalmology and Visual Sciences, University of Nebraska Medical Center, Nebraska, United States, Phone: +1 605 929 5181, e-mail: Brandon.vanderzee@coyotes.usd.edu
Received on: 05 October 2023; Accepted on: 19 June 2024; Published on: 10 July 2024
ABSTRACT
Aim and background: To compare the safety and efficacy of subconjunctival gel stent implantation in the superonasal (SN) vs inferonasal (IN) quadrants in the treatment of glaucoma.
Materials and methods: Patients with a history of IN (n = 29) or SN, (n = 96) gel stent placement with ≥3 months of follow-up were included. Intraocular pressure (IOP) and the number of glaucoma medications were collected preoperatively and postoperatively at months 1, 3, 6, and 12. Safety measures included the number of bleb needlings, complication rate, and additional surgeries.
Results: Mean baseline IOP was 32.4 ± 11.7 mm Hg in the IN group and 21.6 ± 9.2 mm Hg in the SN group (p < 0.01). IOP was similar between groups at 3 months (IN = 15.8, SN = 15.6, p = 0.45), 6 months (IN = 17.4, SN = 15, p = 0.13), and 12 months (IN = 17.9, SN = 14.7, p = 0.15) follow-up. The number of glaucoma medications was also similar at 3 months (p = 0.31), 6 months (p = 0.24), and 12 months (p = 0.39) follow-up. Bleb needling rates were similar with 51.7% (15/29) in the IN group vs 42.7% (41/96) in the SN group (p = 0.39) and subjects requiring further surgery were 17.2% (5/29) in the IN group vs 24.0% (23/96) in the SN group (p = 0.45).
Conclusion: Both IN and SN subconjunctival gel stent placements provide favorable safety and efficacy when treating open-angle glaucoma, with a meaningful decrease in medication use and IOP.
Clinical significance: Implantation of the subconjunctival gel stent in the IN quadrant is an effective and safe alternative to superior implantation in refractory glaucoma.
How to cite this article: Vander Zee BL, Wilson C, Berdahl JP, et al. Superonasal vs Inferonasal Subconjunctival Gel Stent Placement in Patients with Glaucoma. J Curr Glaucoma Pract 2024;18(2):63-67.
Source of support: Nil
Conflict of interest: None
Keywords: Glaucoma, Inferonasal, Safety profile glaucoma drainage device, Subconjunctival gel stent, Superonasal.
INTRODUCTION
Glaucoma remains a leading cause of irreversible blindness across the globe.1 Currently, intraocular pressure (IOP) remains the single proven predisposing factor associated with the development and progression of the disease. The past decade has welcomed the emergence of minimally invasive glaucoma surgery (MIGS). MIGS is a growing category of minimally invasive procedures aimed at IOP reduction while achieving a more favorable safety profile compared to conventional filtering procedures.2,3 These procedures have contributed to a shift in the surgical algorithm and altered the practice patterns of glaucoma specialists.
The most aggressive or least minimally invasive form of MIGS is currently represented by the XEN gel stent (Allergan), a subconjunctival gel stent that channels aqueous into the subconjunctival space in a bleb-forming fashion comparable to traditional filtering procedures. The tube was designed using the Hagen–Poiseuille equation, aimed at preventing hypotony with physiological aqueous production.4 The most common implantation technique for the subconjunctival gel stent is superonasal (SN) via an ab interno insertion, but an ab externo approach may also be utilized, with or without conjunctival dissection.5 The efficacy and safety of the subconjunctival gel stent are well established by a number of prior studies, with complication rates similar to or better than trabeculectomy procedures.6-10
The more common placement of subconjunctival gel stents superiorly is based on experience with other bleb-forming procedures, such as trabeculectomy. The upper eyelids are thought to better protect the bleb surface superiorly, as the inferior conjunctival fornix has a decreased surface area compared to the superior fornix.11 Additionally, the frequency of bleb-associated endophthalmitis is reportedly increased with filtering blebs inferiorly compared to superior blebs.12 Bleb formation with subconjunctival gel stents is usually more low-lying and diffuse than with other procedures, and the ability to place a stent inferonasal (IN) would spare the superior conjunctiva for trabeculectomy or tube shunts, if needed.
This present study aims to evaluate the safety and efficacy of the subconjunctival gel stent placed IN compared to SN implantation. We hypothesized that IN implantation would be similar to SN implantation regarding IOP reduction, glaucoma medication reduction, needling rates, and complications.
MATERIALS AND METHODS
This study was approved by the University of South Dakota Institutional Review Board, which rendered this research exempt (IRB approval number 21-230). Charts were retrospectively evaluated at our institution for patients who had undergone subconjunctival gel stent implantation for refractory glaucoma from 2020 to 2021. Patients must have had a minimum of 3 months of postoperative follow-up at the point of data analysis to be included in this study. Preoperative and postoperative IOP (1, 3, 6, and 12 months of follow-up when available), visual acuity, amount of glaucoma medications, needling events, days from stent implantation to first needling, intraoperative and postoperative complications, and the need for additional surgeries were documented. Needling events were performed at each surgeon’s discretion to control the patients’ IOP targeted to their individual IOP goal. IOP reduction of ≥20% plus IOP below 18 mm Hg with or without medication was defined as a ”qualified success.” IOP reduction of ≥20% with IOP below 18 mm Hg without medication was determined to be a ”complete success.” Patients included in this study had moderate to severe disease, and disease severity staging was based on American Academy of Ophthalmology (AAO) preferred practice pattern guidelines.14
Subconjunctival Gel Stent Implantation Procedure
The XEN45 gel stent (Allergan) was placed using both ab externo and ab interno surgical approaches, consistent with methods previously described in the literature.5 In both techniques, 0.3 mg/mL mitomycin C was instilled within the subconjunctival bleb. If bleb failure resulted due to conjunctival scarring, the bleb needling technique was performed under topical anesthesia using a slit-lamp biomicroscope. Subconjunctival adhesions were lysed using a 27-gauge needle, and bleb patency was confirmed. Mitomycin C 0.3 mg/mL was instilled in the bleb space.
Statistical Analysis
Data were analyzed using Excel’s data analysis tool. Unpaired, one-tailed t-tests were utilized to determine differences in preoperative and postoperative data between groups. Chi-square analysis was used to compare the significance of complications, needling rates, and further surgery between IN and SN groups. Mann–Whitney U tests were performed to assess the normality of the data compared to one-tailed t-tests. Mean IOP before surgery was the mean of the two most recent IOP measurements prior to subconjunctival gel stent implantation. The mean preoperative medication use represented the number of glaucoma medications the patient was using immediately before surgery (combination drops = 2 medications). Postoperative medication data were collected at 3, 6, and 12 months of follow-up (when available). Transient numerical hypotony was characterized as an IOP of <6 mm Hg for <1 week following surgery in a patient with no signs or symptoms of hypotony.
RESULTS
Charts were reviewed for 95 eligible patients (125 eyes) who received a subconjunctival gel stent for glaucoma at our institution between 2020 and 2021. The IN group had an average follow-up of 10.7 months compared to 12.7 months in the SN group. There were 29 eyes with stents implanted within the IN quadrant and 96 eyes with stents placed in the SN quadrant during this period. Of these, 4/29 (13.8%) IN stents and 64/96 (67%) SN stents were inserted with the ab externo approach, the rest being placed via an ab interno approach. Of note, eyes in the IN group experienced a significantly increased number (1.56 vs 0.94, range: 0–4 surgeries) of previous glaucoma procedures compared to the SN cases (p < 0.01). Based on AAO preferred practice pattern guidelines, 26/29 (89.7%) eyes in the IN group and 86/96 (89.6%) eyes in the SN group had severe disease (p = 0.99), with the rest being moderate (Table 1).
IN | SN | p-value | |
---|---|---|---|
Number of eyes | 29 | 96 | *** |
6 months | 24 | 80 | 0.98 |
12 months | 16 | 55 | 0.92 |
Mean age | 74.6 | 77.9 | 0.11 |
Women | 21 (72%) | 55 (57%) | 0.14 |
Men | 8 (28%) | 41 (43%) | 0.14 |
Ab externo | 4 (14%) | 64 (67%) | <0.00001 |
Ab interno | 25 (86%) | 32 (33%) | <0.00001 |
Prior glaucoma surgeries | 1.56 | 0.94 | 0.003 |
Moderate glaucoma | 3 | 10 | 0.99 |
Severe glaucoma | 26 | 86 | 0.99 |
Mean length of f/u | 10.7 months | 12.7 months | 0.04 |
At baseline, the average IOP was significantly elevated in the IN group (32.4 ± 11.8) compared to the SN group (21.6 ± 9.2, p < 0.01), as shown in Figure 1. Both groups had similar mean IOP at 3 months (IN = 15.8, SN = 15.6, p = 0.45), 6 months (IN = 17.4, SN = 15, p = 0.13), and 12 months (IN = 17.9, SN = 14.7, p = 0.15), postoperatively (Table 2).
Mean IOP (mm Hg) | IN | SN | p-value |
---|---|---|---|
Preoperative | 32.4 | 21.6 | <0.01 |
1 month | 15.8 (−16.6) | 13.3 (−8.3) | 0.10 |
3 months | 15.8 (−16.6) | 15.6 (−6) | 0.45 |
6 months | 17.4 (−15) | 15.0 (−6.6) | 0.13 |
12 months | 17.9 (−14.5) | 14.7 (−6.9) | 0.15 |
At 6 months, the average IOP reduction was 46.3% (15.0 ± 11.9 mm Hg) in the IN group and 30.5% (6.6 ± 9.6 mm Hg) within the SN cohort (p < 0.01). Change in IOP from preoperative values was also significant at 3 months (IN = 15.4, SN = 5.9, p < 0.01) and 12 months (IN = 15.4, SN = 6.2, p = 0.01), postoperatively.
To account for variability in follow-up data and outliers, an additional analysis evaluating IOP was conducted, including only eyes with available 12-month follow-up data and excluding outliers [>standard deviation (SD) from the mean], resulting in a subset of 15 patients from the IN group and 52 patients from the SN group. The data remained statistically significant when comparing the preoperative IOP (IN = 29.6, SN = 20.2, p < 0.001). Similar to the full study cohort, the IOP between groups remained nonsignificant when comparing IOP at 3 months (IN = 13.1, SN = 14.5, p = 0.11), at 6 months (IN = 15.3, SN = 14.0, p = 0.21), and 12 months (IN = 14.7, SN = 13.5, p = 0.27), postoperatively.
A significant variation was observed when comparing preoperative glaucoma medications, with more medications being used in the IN group (3.6 ± 1.6) compared to the SN group (2.8 ± 1.1, p < 0.05). No significant difference was observed in the number of medications for glaucoma at 3 months (IN = 1.1, SN = 0.8, p = 0.31), 6 months (IN = 1.4, SN = 1, p = 0.24), and 12 months (IN = 1.7, SN = 1.3, p = 0.29) postsurgical follow-up (Fig. 2). At 6 months of follow-up, 16/29 (55%) eyes in the IN group received ≤1 glaucoma medication compared to 65/96 (68%) in the SN group. In the IN cohort, qualified success was achieved in 18/29 (62%) cases and complete success in 10/29 (34%) cases. In the SN cohort, qualified success was achieved in 49/96 (51%) cases and complete success in 30/96 (31%) cases. Qualified success (p = 0.35) and complete success (p = 0.83) did not show significant differences between the groups.
Postoperatively, 15/29 (51.7%) eyes in the IN category and 41/96 (42.7%) eyes in the SN category needed at least one needling procedure due to IOP elevation, which was not significantly different (p = 0.39) (Table 3). Of those requiring needling, 10/29 (34.5%) IN patients and 7/96 (7.3%) SN patients required multiple needlings (p < 0.01). The average days to first needling were similar in the IN (88.2 days) and SN (134.1 days) groups (p = 0.19). Following the primary subconjunctival gel stent surgery, 5/29 (17.2%) patients in the IN and 23/96 (24%) patients in the SN group required further surgery to reach target IOP (p = 0.45), including subconjunctival gel stent revision or replacement (but not including needling). Among these additional surgeries were two Ahmed tube shunts, two endocyclophotocoagulation and canaloplasties, one goniotomy, and two selective laser trabeculoplasties. All other surgical interventions were subconjunctival gel stent revisions and/or replacements.
IN (n = 29) | SN (n = 96) | p-value | |
---|---|---|---|
%Stents requiring needling | 51.7% (15) | 42.7% (41) | 0.39 |
%Stents requiring >1 needling | 34.5% (10) | 7.3% (7) | <0.01 |
Mean days to needling | 88.2 | 134.1 | 0.19 |
%Requiring further surgery | 17.2% (5) | 24% (23) | 0.45 |
Transient numerical hypotony | 21% (6) | 24% (23) | 0.71 |
To reduce confounding data between ab externo and ab interno surgical techniques, data was compared within each group between these approaches (Table 4). In the IN group, the ab externo and ab interno categories had similar effects on IOP lowering (16.5 vs 12.4, p = 0.63) and glaucoma medication reduction (2.2 vs 2.0, p = 0.74), respectively. Similarly, within the SN group, the ab interno and ab externo groups had comparable effects on IOP lowering (5.4 vs 7.9, p = 0.17) and medication reduction (1.8 vs 1.8, p = 0.93), respectively. Regardless of stent location, stents placed via an ab interno approach had a mean IOP reduction of 10.3 compared to 8.2 in the ab externo cohort (p = 0.29).
Ab interno | Ab externo | p-value | |
---|---|---|---|
SN | |||
IOP reduction | 5.4 | 7.9 | 0.17 |
Medication reduction | 1.8 | 1.8 | 0.93 |
Transient hypotony | 8 | 15 | 0.71 |
%Requiring further surgery | 9 | 14 | 0.39 |
%Stents requiring needling | 13 | 28 | 0.82 |
IN | |||
IOP reduction | 16.5 | 12.4 | 0.63 |
Medication reduction | 2.2 | 2.0 | 0.74 |
Transient hypotony | 5 | 1 | 0.87 |
%Requiring further surgery | 12% (3) | 50% (2) | 0.25 |
%Stents requiring needling | 48% (12) | 75% (3) | 0.41 |
Overall, complication rates were low and not significantly different between both groups. The most frequent complication included brief numerical hypotony (IOP <6 mm Hg) measured during the 1st postoperative week, occurring in 6/29 (21%) eyes in the IN category and 23/96 (24%) eyes in the SN category (p = 0.71). Nearly all of these cases were self-resolved by month 1, and there were no reported visual complications as a result of the hypotony. There was one case of postoperative hypotony that persisted beyond 1 month in each group but self-resolved without the need for further surgery. The second most common complication was subconjunctival gel stent failure requiring another operation to remove and/or replace the stent (IN = 5/29, SN = 17/96, p = 0.92). No events of endophthalmitis, bleb-related infections, persistent clinical hypotony, bleb dysesthesia, choroidal effusions, or loss of vision were documented in this study set. A Mann–Whitney U test was used to evaluate the normality of all categories and found no statistically significant differences.
DISCUSSION
This research reports on the efficacy and safety of subconjunctival gel stents placed in the SN and IN quadrants in patients with refractory glaucoma. Traditionally, these devices have been placed in the SN quadrant, as this area relatively spares the superior and superotemporal quadrants of the conjunctiva for future trabeculectomies or tube shunts if needed.6 In addition, many patients referred for glaucoma surgery have had prior trabeculectomy surgeries in the superior region, causing scarring and changes to the superior conjunctiva and Tenons. The subconjunctival gel stent has successfully controlled IOP while limiting complications when placed SN in patients following previous trabeculectomies,14,15 but this often poses additional surgical difficulties. Operating near an area of previous conjunctival manipulation comes with a risk of increased stent exposure and bleb leaks,16,17 so an alternative location is beneficial in this patient population.
Prior work has found that glaucoma filtering surgeries performed at the inferior limbus due to superior conjunctival scarring remain a safe and effective option for treating glaucoma. Rachmiel et al. reported no significant difference in IOP-lowering and success rates when investigating inferior and superior placements of Ahmed glaucoma drainage devices (GDD).18 Martino et al. reported no significant difference in the average number of glaucoma medications and IOP reduction between superior and inferior glaucoma filtering surgery groups for 2 years following surgery. During the 3rd year of follow-up, the inferior GDD cohort had a significantly greater mean IOP and reoperation rate relative to the superior GDD group.19
In our study, we found that IN stents provided a significant 15.0 mm Hg (46.3%) reduction in IOP compared to a 6.6 mm Hg (30.5%) reduction in the SN group at 6 months. Postoperative IOPs were similar at 1, 3, 6, and 12 months of follow-up when comparing both groups. Qualified success was achieved in 18/29 (62%) cases and complete success in 10/29 (34%) cases in the IN group, while qualified success was attained in 49/96 (51%) cases and complete success in 30/96 (31%) cases in the SN group. Glaucoma medication reduction, change in visual acuity, number of stents requiring needling, days to first needling, and need for further surgery did not vary significantly between the groups. However, a significantly higher proportion of patients in the IN group required multiple needlings.
Düzgün et al. evaluated the effectiveness of subconjunctival gel stents placed IN in 14 patients following failed trabeculectomies. At 12 months of follow-up, they found a 61% reduction in glaucoma medications and an average IOP reduction of 49.3%, with 50% of patients achieving target IOP without glaucoma medications.15 Their 42.8% (6/14) needling rate was similar to our reported rate and comparable to other rates reported within the literature.9,15
Hengerer et al. retrospectively compared IN and SN subconjunctival gel stent implantations. They found no significant difference in qualified success rates (IOP <18 mm Hg and a ≥20% reduction in IOP with or without medications), IOP reduction, and medication reduction at 12 months after surgery. Interestingly, the IN group had significantly lower IOP at the 3-month mark and an overall significantly lower needling percentage compared to the SN group (27 vs 45%). This led the authors to propose that the reduced tension of the lower eyelid may cause less postoperative fibrosis and allow for reduced impedance to aqueous humor outflow in the months following surgery.20 Although we did not observe the same significant difference in IOP lowering effects at 3 months, this theory could partly explain our more substantial IOP reduction in the IN group. In contrast, we did not find a significantly reduced need for needling in the IN cohort but observed a significantly higher frequency of re-needlings (≥2 needlings) in the IN group, despite a similar total number of patients requiring needling between both groups.
The difference in preoperative baseline characteristics between the two groups should also be highlighted. The IN group had significantly higher preoperative IOP, preoperative medication use, and a greater number of previous glaucoma procedures compared to the SN group, despite similar glaucoma severity between the groups (p = 0.99).
There is research showing that blebs located more superiorly have a lower incidence of bleb-related dysesthesia, as has been reported for trabeculectomies.21 Budenz et al. discovered a negative correlation between the amount of bleb enclosed under the lid and bleb dysesthesia, indicating that SN blebs had more discomfort compared to superior blebs.22 There is also concern about a higher risk of bleb-related infection and endophthalmitis with inferiorly located blebs.12,23,24 Overall, most of these studies evaluated these complications following trabeculectomies and may not directly apply to blebs produced by the subconjunctival stent device studied herein.
Although there was a limited sample size in the IN group, there were no reported cases of bleb dysesthesia, bleb-related infections, or endophthalmitis in either cohort. This is consistent with previous research evaluating the safety of IN subconjunctival gel implants.15,20 These findings may be related to the fact that blebs following subconjunctival gel stent implantation have a different morphology and healing process compared to traditional blebs, as measured with anterior chamber optical coherence tomography.25 Bleb morphology and function play a crucial role in the success of these surgeries and are related to the incidence of bleb-related complications.26-28 These results, although limited to a single study, suggest that minimally invasive IN implantation may not be associated with an increased risk of endophthalmitis due to their altered bleb morphology. However, further study is certainly needed to confirm these findings.
This study is not without limitations. As a retrospective study, it has inherent limitations including lack of uniform follow-up, differences in sample size between the two groups, and variability in follow-up duration. To address these discrepancies, a sensitivity analysis was performed, comparing only patients with a full 12 months of follow-up and excluding outliers, which showed no changes in statistical significance when comparing IOP at different time points. Additionally, the IN group appeared to have more advanced glaucoma, with higher baseline IOP, more glaucoma medications, and more previous glaucoma surgeries, which could impact the comparison between the groups. However, a large, prospective, randomized controlled trial would be the optimal approach to assess the safety and efficacy between these two subconjunctival stent locations.
CONCLUSION
This study demonstrates that IN subconjunctival gel stent implantation provides a comparable IOP-lowering benefit compared to SN stents, with a trend toward enhanced IOP reduction in the IN group. Additionally, qualified and complete success rates, medication reduction, needling rates, complications, and the need for further surgery were similar in the two groups. More studies are needed to confirm these findings and improve our understanding of how bleb location influences glaucoma treatment.
Clinical Significance
This article compares the efficacy and safety between SN and IN subconjunctival gel stents for treating refractory glaucoma. Our research, despite its limited sample size, demonstrates that IN placement of subconjunctival stents provides a comparable IOP and glaucoma medication lowering effect compared to the traditional superior approach. Overall, the results of this study suggest that IN quadrant placement is an acceptable approach and may be a strategy to avoid previous scarring or spare the superior conjunctiva, potentially enabling more patients to receive subconjunctival gel stents for the treatment of refractory glaucoma.
REFERENCES
1. Tham YC, Li X, Wong TY, et al. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology 2014;121(11):2081–2090. DOI: 10.1016/j.ophtha.2014.05.013
2. Gedde SJ, Schiffman JC, Feuer WJ, et al. Treatment outcomes in the tube versus trabeculectomy (TVT) study after five years of follow-up. Am J Ophthalmol 2012;153(5):789.e2–803.e2. DOI: 10.1016/j.ajo.2011.10.026
3. Saheb H, Ahmed II. Micro-invasive glaucoma surgery: current perspectives and future directions. Curr Opin Ophthalmol 2012;23(2):96–104. DOI: 10.1097/ICU.0b013e32834ff1e7
4. Sheybani A, Reitsamer H, Ahmed II. Fluid dynamics of a novel micro-fistula implant for the surgical treatment of glaucoma. Invest Ophthalmol Vis Sci 2015;56(8):4789–4795. DOI: 10.1167/iovs.15-16625
5. Fea AM, Durr GM, Marolo P, et al. XEN® gel stent: a comprehensive review on its use as a treatment option for refractory glaucoma. Clin Ophthalmol 2020;14:1805–1832. DOI: 10.2147/OPTH.S178348
6. Tan S, Walkden A, Au L. One-year result of XEN45 implant for glaucoma: efficacy, safety, and postoperative management. Eye 2018;32(2):324–332. DOI: 10.1038/eye.2017.16
7. Schlenker MB, Gulamhusein H, Conrad-Hengerer I, et al. Efficacy, safety, and risk factors for failure of standalone ab interno gelatin microstent implantation versus standalone trabeculectomy. Ophthalmology 2017;124(11):1579–1588. DOI: 10.1016/j.ophtha.2017.05.004
8. De Gregorio A, Pedrotti E, Russo L, et al. Minimally invasive combined glaucoma and cataract surgery: clinical results of the smallest ab interno gel stent. Int Ophthalmol 2018;38(3):1129–1134. DOI: 10.1007/s10792-017-0571-x
9. Widder RA, Dietlein TS, Dinslage S, et al. The XEN45 Gel Stent as a minimally invasive procedure in glaucoma surgery: success rates, risk profile, and rates of re-surgery after 261 surgeries. Graefes Arch Clin Exp Ophthalmol 2018;256(4):765–771. DOI: 10.1007/s00417-018-3899-7
10. Olgun A, Duzgun E, Yildiz AM, et al. XEN gel stent versus trabeculectomy: short-term effects on corneal endothelial cells. Eur J Ophthalmol 2021;31(2):346–353. DOI: 10.1177/1120672120924339
11. Negi AK, Kiel AW, Vernon SA. Does the site of filtration influence the medium to long term intraocular pressure control following microtrabeculectomy in low risk eyes? Br J Ophthalmol 2004;88(8):1008–1011. DOI: 10.1136/bjo.2003.028811
12. Greenfield DS, Suñer IJ, Miller MP, et al. Endophthalmitis after filtering surgery with mitomycin. Arch Ophthalmol 1996;114(8):943–949. DOI: 10.1001/archopht.1996.01100140151007
13. Gedde SJ, Vinod K, Wright MM, et al. Primary open-angle glaucoma preferred practice pattern®. Ophthalmology 2021;128(1):P71–P150. DOI: 10.1016/j.ophtha.2020.10.022
14. Karimi A, Hopes M, Martin KR, et al. Efficacy and safety of the ab-interno Xen gel stent after failed trabeculectomy. J Glaucoma 2018;27(10):864–868. DOI: 10.1097/IJG.0000000000001044
15. Düzgün E, Olgun A, Karapapak M, et al. Outcomes of XEN gel stent implantation in the inferonasal quadrant after failed trabeculectomy. J Curr Glaucoma Pract 2021;15(2):64–69. DOI: 10.5005/jp-journals-10078-1304
16. Fea A, Cannizzo PM, Consolandi G, et al. Managing drawbacks in unconventional successful glaucoma surgery: a case report of stent exposure. Case Rep Ophthalmol Med 2015;2015:847439. DOI: 10.1155/2015/847439
17. Lapira M, Cronbach N, Shaikh A. Extrusion and breakage of XEN gel stent resulting in endophthalmitis. J Glaucoma 2018;27(10):934–935. DOI: 10.1097/IJG.0000000000001058
18. Rachmiel R, Trope G, Buys Y, et al. Intermediate-term outcome and success of superior versus inferior ahmed glaucoma valve implantation. J Glaucoma 2008;17(7):584–590. DOI: 10.1097/IJG.0b013e31816299bc
19. Martino AZ, Iverson S, Feuer WJ, et al. Surgical outcomes of superior versus inferior glaucoma drainage device implantation. J Glaucoma 2015;24(1):32–36. DOI: 10.1097/IJG.0b013e318287ac8f
20. Hengerer FH, Auffarth G, Conrad-Hengerer I. Nasal superior versus nasal inferior implantation of the Xen45 gel stent – one year results. J Ophthalmol Vision Res 2019;1(1):1. DOI: 10.5281/zenodo.3373284
21. Sekaran A, Karimi A, Lindfield D. Hypertrophic dysaesthetic blebs following ab-interno gel stent (Xen) glaucoma surgery: management and ‘redirect’ revision surgery. Clin Exp Ophthalmol 2018;46(9):1093–1095. DOI: 10.1111/ceo.13335
22. Budenz DL, Hoffman K, Zacchei A. Glaucoma filtering bleb dysesthesia. Am J Ophthalmol. 2001;131(5):626–630. DOI: 10.1016/s0002-9394(00)00901-6
23. Soltau JB, Rothman RF, Budenz DL, et al. Risk factors for glaucoma filtering bleb infections. Arch Ophthalmol 2000;118(3):338–342. DOI: 10.1001/archopht.118.3.338
24. Caronia RM, Liebmann JM, Friedman R, et al. Trabeculectomy at the inferior limbus. Arch Ophthalmol 1996;114(4):387–391. DOI: 10.1001/archopht.1996.0110013038300
25. Lenzhofer M, Strohmaier C, Hohensinn M, et al. Longitudinal bleb morphology in anterior segment OCT after minimally invasive transscleral ab interno glaucoma gel microstent implantation. Acta Ophthalmol 2019;97(2):e231–e237. DOI: 10.1111/aos.13902
26. Luo M, Zhu Y, Xiao H, et al. Characteristic assessment of angiographies at different depths with AS-OCTA: implication for functions of post-trabeculectomy filtering bleb. J Clin Med 2022;11(6):1661. DOI: 10.3390/jcm11061661
27. Picht G, Grehn F. Classification of filtering blebs in trabeculectomy: biomicroscopy and functionality. Curr Opin Ophthalmol 1998;9(2):2–8. DOI: 10.1097/00055735-199804000-00002
28. Kim E-A, Law SK, Coleman AL, et al. Long-term bleb-related infections after trabeculectomy: incidence, risk factors, and influence of bleb revision. Am J Ophthalmol 2015;159(6):1082–1091. DOI: 10.1016/j.ajo.2015.03.001
________________________
© The Author(s). 2024 Open Access. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.